What was found
PIT - Q4, Z-CHANNEL, CORROSION; 1 INCH DIAMETER AREA, LEVEL 1, TASK NR C53-107-01, MED LOWER THRESHOLD, STA 312-344. MANUFACTURED AND INSTALLED NEW Z-CHANNEL IAW DWG 65-17688.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q4, Z-CHANNEL, CORROSION; 1 INCH DIAMETER AREA, LEVEL 1, TASK NR C53-107-01, MED LOWER THRESHOLD, STA 312-344. MANUFACTURED AND INSTALLED NEW Z-CHANNEL IAW DWG 65-17688.