What was found
PIT, Q4, Z-ANGLE, 26 INCHES, CORROSION; LEVEL 1; TASK NR C53-107-02, AFT ENTRY DOOR Z-ANGLE AROUND SCREW HOLES, STA 962-986. REPLACED Z-ANGLE, DRILLED HOLES IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT, Q4, Z-ANGLE, 26 INCHES, CORROSION; LEVEL 1; TASK NR C53-107-02, AFT ENTRY DOOR Z-ANGLE AROUND SCREW HOLES, STA 962-986. REPLACED Z-ANGLE, DRILLED HOLES IAW SRM 51-10-02.