What was found
PIT, C3; SKIN, .2500 INCH CRACK, BETWEEN STR 13/16R AND FRA 947.5. 11 INCH W X 9.5 INCH H FILLER, ALONG WITH 10 INCH W X 13.5 H DOUBLER IAW SRM 53-60-01, FIG 207.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT, C3; SKIN, .2500 INCH CRACK, BETWEEN STR 13/16R AND FRA 947.5. 11 INCH W X 9.5 INCH H FILLER, ALONG WITH 10 INCH W X 13.5 H DOUBLER IAW SRM 53-60-01, FIG 207.