What was found
CLT, C-4, FLOORBEAM, .5 INCH AREAS SEVERAL SPOTS, LEVEL 1 CORROSION, STA 377.7 FROM LBL62 TO RBL12. ACCOMPLISHED (T) CAP REPAIR IAW TR 53-15-01 AND EA 95899.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT, C-4, FLOORBEAM, .5 INCH AREAS SEVERAL SPOTS, LEVEL 1 CORROSION, STA 377.7 FROM LBL62 TO RBL12. ACCOMPLISHED (T) CAP REPAIR IAW TR 53-15-01 AND EA 95899.