What was found
PIT - Q5, FLOOR SUPPORT, .1250 INCH BY .1250 INCH AREA, CORROSION; LEVEL 1; TASK NRC53-107-02, FASTENER HOLE AT STA 947 RBL 20. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR ANGLE, SHIM AND FILLER IAW EA 79192.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q5, FLOOR SUPPORT, .1250 INCH BY .1250 INCH AREA, CORROSION; LEVEL 1; TASK NRC53-107-02, FASTENER HOLE AT STA 947 RBL 20. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR ANGLE, SHIM AND FILLER IAW EA 79192.