What was found
PIT, Q5, WEB FRAME, 3 INCH CRACK AT FWD ENTRY DOOR LOWER WEB FRAME FORWARD CORNER. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 52-10-02 FIG 1, SRM 51-70-11 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.