What was found
PIT - Q1 -CLIP, .1250 INCH CRACK FROM RIVET AT FRAME STA 663.75, STR S10L. REMOVED AND REPLACED STRINGER TIE CLIP IAW SRM 51-10-2, 51-40-03 AND MFG DWG 65-46541.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q1 -CLIP, .1250 INCH CRACK FROM RIVET AT FRAME STA 663.75, STR S10L. REMOVED AND REPLACED STRINGER TIE CLIP IAW SRM 51-10-2, 51-40-03 AND MFG DWG 65-46541.