What was found
PIT - Q1 - FRAME, .1250 INCH CRACK, BS787 AT S9L-S8L. CUT OUT DAMAGE AND INSTALLED NESTED REPAIR ANGLES IAW TYP REP 53-10-02A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q1 - FRAME, .1250 INCH CRACK, BS787 AT S9L-S8L. CUT OUT DAMAGE AND INSTALLED NESTED REPAIR ANGLES IAW TYP REP 53-10-02A.