What was found
BFM - S1 - FLOOR SUPPORT, 2 INCHES X 12 INCHES X 0.020 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FLOOR BET FR 16, 20, BL-Y1292. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 - FLOOR SUPPORT, 2 INCHES X 12 INCHES X 0.020 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-220-53500, MAIN CABIN FLOOR BET FR 16, 20, BL-Y1292. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.