What was found
BFM - S1 - BEAM, 18 INCHES X 2 INCHES X .03 INCH AREA, CORROSION; LEVEL 2; TSK NR JA 260-53500-004, MAINT CABIN FLOOR Y1292 BET C66 AND C68. REMOVED AND REPLACED FLOORBEAM IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.