What was found
BFM - S1 - FLOOR SUPPORT, 1.5 INCH X 2 INCHES X .040 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-200-53500, BTW FR 16 AND 20, Y1292, FLOOR SUPPORT. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 - FLOOR SUPPORT, 1.5 INCH X 2 INCHES X .040 INCH AREA; CORROSION; LEVEL 2; TASK NR JA-200-53500, BTW FR 16 AND 20, Y1292, FLOOR SUPPORT. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-11-14, 51-42-11.