What was found
BFM - S1 - BEAM, 2 INCHES X 2 INCHES X .050 INCH AREA, CORROSION; LEVEL 1; TASK NR JA-220-53500; MAIN CABIN FLOOR AT FR 16, BL-Y765. INSTALLED FILLER AND REPAIR ANGLE IAW SRM 53-00-14, 51-42-11, 53-11-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 - BEAM, 2 INCHES X 2 INCHES X .050 INCH AREA, CORROSION; LEVEL 1; TASK NR JA-220-53500; MAIN CABIN FLOOR AT FR 16, BL-Y765. INSTALLED FILLER AND REPAIR ANGLE IAW SRM 53-00-14, 51-42-11, 53-11-14.