What was found
BFM - S1 CK - CABIN FLOOR SUPPORT, 3 INCH X 1 INCH X .040 INCH DEEP, CORROSION; LEVEL 2; TASK NR JA-220-53500, FR 16, Y1292, MAIN CABIN FLOOR SUPPORT. INSTALLED DOUBLER AND FILLER REPAIR IAW SRM 53-11-15, FIG 203.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 CK - CABIN FLOOR SUPPORT, 3 INCH X 1 INCH X .040 INCH DEEP, CORROSION; LEVEL 2; TASK NR JA-220-53500, FR 16, Y1292, MAIN CABIN FLOOR SUPPORT. INSTALLED DOUBLER AND FILLER REPAIR IAW SRM 53-11-15, FIG 203.