What was found
BFM - S1 CK - BEAM, 1.5 INCH X 1 INCH X .025 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN FLOOR BTW FR 66 AND FR 68, BL Y1292. REPLACED BEAM IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.