What was found
PIT - Q4 - LOWER SKIN SURFACE, COMPOSITE DAMAGE, .3750 INCH GOUGE, COMPOSITE DAMAGE - SINGLE LAYER, RT ELEVATOR AT STA 64 + 7 INCH FROM FWD SPAR. REPAIRED DAMAGED AREA, APPLIED WET LAY UP REPAIR PER SRM AND EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q4 - LOWER SKIN SURFACE, COMPOSITE DAMAGE, .3750 INCH GOUGE, COMPOSITE DAMAGE - SINGLE LAYER, RT ELEVATOR AT STA 64 + 7 INCH FROM FWD SPAR. REPAIRED DAMAGED AREA, APPLIED WET LAY UP REPAIR PER SRM AND EA.