What was found
PIT - Q1 - TOP COMPOSITE LAYER, 2 INCHES X 2 INCH AREA, SINGLE LAYER DAMAGE. RUDDER LT SIDE 105./5 INCHES FROM BOTTOM AND .3750 FROM L/E. PREPARED AREA, LIGHT SANDING, INSTALLED MULTI PLY REPAIR IAW SRM AND EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q1 - TOP COMPOSITE LAYER, 2 INCHES X 2 INCH AREA, SINGLE LAYER DAMAGE. RUDDER LT SIDE 105./5 INCHES FROM BOTTOM AND .3750 FROM L/E. PREPARED AREA, LIGHT SANDING, INSTALLED MULTI PLY REPAIR IAW SRM AND EA.