What was found
PIT - Q5 - FRAME, 3 INCH X 3 INCH AREA, CORROSION; LEVEL 1; TASK NR C53-208-01, STA 492.5 BETWEEN STR 27R AND 28R FRAME. INSTALLED DOUBLERS IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q5 - FRAME, 3 INCH X 3 INCH AREA, CORROSION; LEVEL 1; TASK NR C53-208-01, STA 492.5 BETWEEN STR 27R AND 28R FRAME. INSTALLED DOUBLERS IAW SRM. (K)