What was found
BFM - S1 CHECK, FLOORBEAM, 2.4 INCH L X 1.81 INCH X .066 INCH D, CORROSION; LEVEL 2; TASK NR JA260-53500-007, FR 66,Y765, Z240. REMOVED AND REPLACED WITH NEW FLOORBEAM IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 CHECK, FLOORBEAM, 2.4 INCH L X 1.81 INCH X .066 INCH D, CORROSION; LEVEL 2; TASK NR JA260-53500-007, FR 66,Y765, Z240. REMOVED AND REPLACED WITH NEW FLOORBEAM IAW SRM. (K)