What was found
BFM - S1-CHECK - BEAM, 2.0 INCH X .75 INCH X 0.052 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN FLOOR BETWEEN FR 68-69, BL Y1292. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1-CHECK - BEAM, 2.0 INCH X .75 INCH X 0.052 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-260-53500, MAIN CABIN FLOOR BETWEEN FR 68-69, BL Y1292. REMOVED AND REPLACED BEAM ASSY IAW SRM. (K)