What was found
BFM - S1 CHECK - FLOOR PANEL, .500 INCH X .300 INCH X 0.032 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-250-53100-002. FLOOR PANEL NR 262FF, Y1292, FR 66-68. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1 CHECK - FLOOR PANEL, .500 INCH X .300 INCH X 0.032 INCH AREA, CORROSION; LEVEL 2; TASK NR JA-250-53100-002. FLOOR PANEL NR 262FF, Y1292, FR 66-68. REMOVED AND REPLACED WITH NEW PART IAW SRM. (K)