What was found
BFM - S1-CHECK - FLOOR BEAM, 16 INCHES L X 2 INCHES X .027 INCH D, CORROSION; LEVEL 2; TASK JA-220-53500-001, BEAM Y1292, FR 16-20. REMOVED AND REPLACED WITH NEW BEAM IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S1-CHECK - FLOOR BEAM, 16 INCHES L X 2 INCHES X .027 INCH D, CORROSION; LEVEL 2; TASK JA-220-53500-001, BEAM Y1292, FR 16-20. REMOVED AND REPLACED WITH NEW BEAM IAW SRM. (K)