What was found
PIT - FOUND FRAME CORRODED 1 INCH IN DIAMETER, STATION 492.4, FORWARD CARGO DOOR FRAME AFT LOWER STOP FITTING. CUT OUT DAMAGE, TRIMMED ANGLE TO SIZE AND SHAPE, FABRICATED FILLER, TREATED, PRIMED PER SRM 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CORRODED 1 INCH IN DIAMETER, STATION 492.4, FORWARD CARGO DOOR FRAME AFT LOWER STOP FITTING. CUT OUT DAMAGE, TRIMMED ANGLE TO SIZE AND SHAPE, FABRICATED FILLER, TREATED, PRIMED PER SRM 51-70-11. (M)