What was found
PIT - FOUND BEAM CRACKED .75 INCH, STATION 616 BELOW RT SIDE CREASE BEAM. ROUTED OUT CRACK, INSTALLED FILLER AND REPAIR ANGLE PER TYPICAL REP 53-62-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CRACKED .75 INCH, STATION 616 BELOW RT SIDE CREASE BEAM. ROUTED OUT CRACK, INSTALLED FILLER AND REPAIR ANGLE PER TYPICAL REP 53-62-01. (M)