What was found
PIT - Q3 - FLOOR SUPPORT, 1 INCH X 2 INCH AT 3 AREAS; CORROSION; LEVEL 1; TASK NR C53-107-02, STA 947.5-966 RBBL. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-10-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q3 - FLOOR SUPPORT, 1 INCH X 2 INCH AT 3 AREAS; CORROSION; LEVEL 1; TASK NR C53-107-02, STA 947.5-966 RBBL. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-10-00.