What was found
PIT - Q6 - FRAME, .2500 INCH CRACK; BS 907 FRAME BETWEEN STRINGERS S-1 AND S-2R. DOUBLERS INSTALLED IAW SRM 53-00-07, FIG 201 WITH MINOR DEVIATION IAW EA 79620. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q6 - FRAME, .2500 INCH CRACK; BS 907 FRAME BETWEEN STRINGERS S-1 AND S-2R. DOUBLERS INSTALLED IAW SRM 53-00-07, FIG 201 WITH MINOR DEVIATION IAW EA 79620. (K)