What was found
PIT - Q6 - INTERCOSTAL, .5 INCH CRACK; LT AND RT SIDES OF FWD ATTACH ANGLE AND INTERCOSTAL BELOW CABIN FLOOR STA 254 BL0. MANUFACTURED NEW INTERCOSTAL IAW MFG DWG 65-45833 AND SRM 51-20-01, 51-40-00. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q6 - INTERCOSTAL, .5 INCH CRACK; LT AND RT SIDES OF FWD ATTACH ANGLE AND INTERCOSTAL BELOW CABIN FLOOR STA 254 BL0. MANUFACTURED NEW INTERCOSTAL IAW MFG DWG 65-45833 AND SRM 51-20-01, 51-40-00. (K)