What was found
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY .75 INCH AREA, FLOORBEAM STATION 328 RBBL 24.50 LBBL 24.50. CORROSION LEVEL 1. REMOVED CORROSION, FABRICATED STRAP REPAIR PER SRM 53-00-51 PAGE 212-215 AND 53-10-51 PAGE 114. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY .75 INCH AREA, FLOORBEAM STATION 328 RBBL 24.50 LBBL 24.50. CORROSION LEVEL 1. REMOVED CORROSION, FABRICATED STRAP REPAIR PER SRM 53-00-51 PAGE 212-215 AND 53-10-51 PAGE 114. (M)