What was found
PIT - FOUND INTERCOSTAL CORRODED 2 INCH BY 2 INCH AND 4 INCH BY 4 INCH, BS 947 TO 967 LBL 50. CORROSION LEVEL 1, TASK C53-107-102. REPLACED WITH BOEING PART PER SRM 51-40-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND INTERCOSTAL CORRODED 2 INCH BY 2 INCH AND 4 INCH BY 4 INCH, BS 947 TO 967 LBL 50. CORROSION LEVEL 1, TASK C53-107-102. REPLACED WITH BOEING PART PER SRM 51-40-04. (M)