What was found
PIT - FOUND FRAME CLIP CRACKED .5 INCH, STATION 706 S11L. FABRICATED AND INSTALLED NEW CLIP PER SRM 51-46-03 AND 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CLIP CRACKED .5 INCH, STATION 706 S11L. FABRICATED AND INSTALLED NEW CLIP PER SRM 51-46-03 AND 51-70-11. (M)