What was found
PIT - FOUND INTERCOSTAL CRACKED .5 INCH, 2 FASTENER HOLES STATION 500G TO 520 BL 0. INSTALLED INTERCOSTAL PER 53-30-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND INTERCOSTAL CRACKED .5 INCH, 2 FASTENER HOLES STATION 500G TO 520 BL 0. INSTALLED INTERCOSTAL PER 53-30-51. (M)