What was found
PIT - FOUND FRAME CRACKED TWO PLACES .125 INCH LONG, STATION 500A BETWEEN STRINGER 8LT AND 9L OVERHEAD BIN LOWER ATTACH POINT. REINFORCED WITH PREFABRICATED DOUBLERS PER TYPICAL REPAIR 53-10-20A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED TWO PLACES .125 INCH LONG, STATION 500A BETWEEN STRINGER 8LT AND 9L OVERHEAD BIN LOWER ATTACH POINT. REINFORCED WITH PREFABRICATED DOUBLERS PER TYPICAL REPAIR 53-10-20A. (M)