What was found
PIT - FOUND CLIP CORRODED 1 INCH BY 3 INCH AREA, FRAME 795, STRINGER 27R. CORROSION LEVEL 1, TASK C53-208-01. CUT OUT DAMAGE AND INSTALLED DOUBLER REPAIR PER EA 79752, SRM 53-00-07 FIG 207. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CLIP CORRODED 1 INCH BY 3 INCH AREA, FRAME 795, STRINGER 27R. CORROSION LEVEL 1, TASK C53-208-01. CUT OUT DAMAGE AND INSTALLED DOUBLER REPAIR PER EA 79752, SRM 53-00-07 FIG 207. (M)