What was found
PIT - FOUND STRINGER SPLICE CRACKED 1 INCH IN TWO LOCATIONS, BS 908 S4L AND S4R. REMOVED TWO SPLICES, MANUFACTURED NEW AND INSTALLED PER SRM 51-40-02 AND DWG NR 65-51698. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRINGER SPLICE CRACKED 1 INCH IN TWO LOCATIONS, BS 908 S4L AND S4R. REMOVED TWO SPLICES, MANUFACTURED NEW AND INSTALLED PER SRM 51-40-02 AND DWG NR 65-51698. (M)