What was found
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH AREA, FLOOR SUPPORT BEAM S-26R BS 787-867. CORROSION LEVEL 1, TASK C53-208-01. REMOVED AND REPLACED FLOOR SUPPORT BEAM WITH FABRICATED BEAM PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH AREA, FLOOR SUPPORT BEAM S-26R BS 787-867. CORROSION LEVEL 1, TASK C53-208-01. REMOVED AND REPLACED FLOOR SUPPORT BEAM WITH FABRICATED BEAM PER SRM 51-40-02. (M)