What was found
CLT - FOUND STRINGER SPLICE WITH TWO CRACKS .250 INCH, EMANATING FROM 2 RIVETS IN S4L SPLICE WEB AT STATION 907. REPAIRED IAW SRM 51-20-02 AND 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND STRINGER SPLICE WITH TWO CRACKS .250 INCH, EMANATING FROM 2 RIVETS IN S4L SPLICE WEB AT STATION 907. REPAIRED IAW SRM 51-20-02 AND 51-40-02. (M)