What was found
FOUND SHEAR WEB CORRODED 10 INCHES BY 27 INCHES, BS 1016 FLOOR BL 0 - LBL 27. CORROSION LEVEL 1, TASK C53-202-01. FABRICATED NEW SHEAR WEB AND INSTALLED NEW PARTS PER SRM 53-60-51, 51-30-01, 51-24-00, 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SHEAR WEB CORRODED 10 INCHES BY 27 INCHES, BS 1016 FLOOR BL 0 - LBL 27. CORROSION LEVEL 1, TASK C53-202-01. FABRICATED NEW SHEAR WEB AND INSTALLED NEW PARTS PER SRM 53-60-51, 51-30-01, 51-24-00, 51-40-02. (M)