What was found
BFM - FOUND STRINGER SPLICE CRACKED .750 INCH, FASTENERS MOUNTING HOLE, AFT CABIN LEFT CEILING, STRINGER 4L AT BS 908. FABRICATED PARTS, INSTALLED FABRICATED CHANNEL ON STRINGER SPLICE PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND STRINGER SPLICE CRACKED .750 INCH, FASTENERS MOUNTING HOLE, AFT CABIN LEFT CEILING, STRINGER 4L AT BS 908. FABRICATED PARTS, INSTALLED FABRICATED CHANNEL ON STRINGER SPLICE PER SRM 51-40-02. (M)