What was found
FOUND STRINGER CORRODED 2 INCHES BY .6 INCHES BY .045 INCH DEEP, STRINGER 29L, STATION 1720. REMOVED DAMAGED SECTION. INSTALLED NEW STRINGER WITH SPLICES PER SRM 53-00-03 PAGE 101 AND FIG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STRINGER CORRODED 2 INCHES BY .6 INCHES BY .045 INCH DEEP, STRINGER 29L, STATION 1720. REMOVED DAMAGED SECTION. INSTALLED NEW STRINGER WITH SPLICES PER SRM 53-00-03 PAGE 101 AND FIG 201. (M)