What was found
BFM - FOUND STRINGER SPLICE CRACKED .5 INCH, RT CEILING AT STATION 987 STRINGER 4. FABRICATED PARTS AND INSTALLED FABRICATED SPLICE AND SHEAR TIE IAW SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND STRINGER SPLICE CRACKED .5 INCH, RT CEILING AT STATION 987 STRINGER 4. FABRICATED PARTS AND INSTALLED FABRICATED SPLICE AND SHEAR TIE IAW SRM 51-40-02. (M)