What was found
BFM - FOUND CAP CORRODED 2 INCH BY 51.5 INCH BY .025 INCH AND .018 INCH, STATION 344 LBL 20 - RBL 20. REMOVED FLOORBEAM CAP, APPROX 51.5; FABRICATED NEW CAP AND INSTALLED PER SRM 53-10-51, 51-20-01, 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND CAP CORRODED 2 INCH BY 51.5 INCH BY .025 INCH AND .018 INCH, STATION 344 LBL 20 - RBL 20. REMOVED FLOORBEAM CAP, APPROX 51.5; FABRICATED NEW CAP AND INSTALLED PER SRM 53-10-51, 51-20-01, 51-40-02. (M)