What was found
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH AREA .030 INCH DEEP, TOP FLANGE OF FLOOR SUPPORT AT -Y20, FRAME 66, AFT CABIN AREA. REMOVED AND REPLACED FLOOR SUPPORT, BOLTED INSTALLATION PER SRM 53-11-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH AREA .030 INCH DEEP, TOP FLANGE OF FLOOR SUPPORT AT -Y20, FRAME 66, AFT CABIN AREA. REMOVED AND REPLACED FLOOR SUPPORT, BOLTED INSTALLATION PER SRM 53-11-14. (M)