What was found
PIT - FOUND FLOORBEAM CORRODED 20 INCHES BY 3 INCHES, AT Y 48 INCHES BETWEEN FRAME 66-68. REPLACED FLOORBEAM PER SRM 51-72-11 AND D53472780 A/D DWG. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 20 INCHES BY 3 INCHES, AT Y 48 INCHES BETWEEN FRAME 66-68. REPLACED FLOORBEAM PER SRM 51-72-11 AND D53472780 A/D DWG. (M)