What was found
PIT - FOUND FLOORBEAM CORRODED 20 INCH BY 3 INCH WIDESPREAD AT Y48 FRAME 66. REPLACED FLOORBEAM PER AIRBUS DWG D53472780 AND SRM 51-72-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 20 INCH BY 3 INCH WIDESPREAD AT Y48 FRAME 66. REPLACED FLOORBEAM PER AIRBUS DWG D53472780 AND SRM 51-72-11. (M)