What was found
PIT - FOUND FLOOR SUPPORT CORRODED 3 INCHES BY 3 INCHES, AT FRAME 67 AND Y - 28 INCHES. CORROSION LEVEL 1, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 3 INCHES BY 3 INCHES, AT FRAME 67 AND Y - 28 INCHES. CORROSION LEVEL 1, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART. (M)