What was found
PIT - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 10 INCHES, Y1292 FLOOR SUPPORT FROM C-66 TO C-70. DEFECTIVE PART REPLACED WITH IDENTICAL PART PER SRM 51-72-11 AND DWG D53472815. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 10 INCHES, Y1292 FLOOR SUPPORT FROM C-66 TO C-70. DEFECTIVE PART REPLACED WITH IDENTICAL PART PER SRM 51-72-11 AND DWG D53472815. (M)