What was found
PIT - FOUND FLOORBEAM ANGLE BRACKET CORRODED 2 INCHES BY 1 INCH, FRAME 17 - Y 31 INCH. CORROSION LEVEL 2, TASK JA-220-53500. FABRICATED ANGLE BRACKET PER SRM 53-11-15. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM ANGLE BRACKET CORRODED 2 INCHES BY 1 INCH, FRAME 17 - Y 31 INCH. CORROSION LEVEL 2, TASK JA-220-53500. FABRICATED ANGLE BRACKET PER SRM 53-11-15. (M)