What was found
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH DIAMETER AREA, FLOOR SUPPORT AT Y765 AND C-66. CORROSION LEVEL 2, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-72-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH DIAMETER AREA, FLOOR SUPPORT AT Y765 AND C-66. CORROSION LEVEL 2, TASK JA-260-53500. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-72-11. (M)