What was found
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH AREA, FRAME 17 BLL 18 INCHES. CORROSION LEVEL 2, TASK JA-220-53500. REPLACED FLOORBEAM PER SRM 53-11-14, DWG B2D53112826. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.