What was found
PIT - S2 - FITTING, 6 INCH X 2 INCH AND 2 INCH X 2 INCH, CORROSION; LEVEL 1; TASK JA-260-53500, BETWEEN FR 69 AND 70 AT -Y48 INCH ON SHEAR PLATE (TIE). REPLACED SHEAR TIE, RT SIDE IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S2 - FITTING, 6 INCH X 2 INCH AND 2 INCH X 2 INCH, CORROSION; LEVEL 1; TASK JA-260-53500, BETWEEN FR 69 AND 70 AT -Y48 INCH ON SHEAR PLATE (TIE). REPLACED SHEAR TIE, RT SIDE IAW SRM. (K)