What was found
FOUND FLOORBEAM CORRODED 3 INCHES, BS 967, LBL 43. FABRICATED NEW T-CAP FOR FLOORBEAM PER SRM 53-00-51, SAME AS PREVIOUS REPAIR. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CORRODED 3 INCHES, BS 967, LBL 43. FABRICATED NEW T-CAP FOR FLOORBEAM PER SRM 53-00-51, SAME AS PREVIOUS REPAIR. (M)